Multi-level access and seamless monitoring.

Data centres

In a data centre, what matters is who was at which cabinet and when, and how early a smouldering fire is detected. We install access control down to the individual server cabinet, early fire detection with aspirating smoke detection, video recording and monitoring of the building envelope and security zones to VdS.

  • Access down to the rackDigital half cylinders allow individual permissions for each server cabinet.
  • Early fire detection in the cabinetAspirating smoke detection systems continuously draw air samples from the server cabinet and detect a smouldering fire at an early stage.
  • Intruder detection to VdSWe design and install the monitoring of the building envelope and security zones to VdS guidelines.
  • Evidence for auditsAccess events and maintenance are logged and can be compiled as a report.

Electronic access control and locking systems

With the SALTO Space system platform, doors, gates, lifts, vehicle entrances and furniture can be integrated into one uniform, wireless access control system. Mechanical keys are no longer needed. Permissions are granted and withdrawn centrally in web-based software, including for several sites. We are a certified OEM partner of SALTO.

SALTO product overview: readers, fittings and cylinders

Digital locking, contactless

  • Retrofitting of smart door components (digital cylinders or digital fittings)
  • Multi-tenant web software
  • Opening by RFID chip or smartphone
  • Cost-effective installation without cabling

Electronic locking of server cabinets

  • Retrofitting of smart door components (digital half cylinders)
  • Individual authorisations for every server cabinet
  • Opening by RFID chip or smartphone
  • Cost-effective installation without cabling

Components

  • XS4 One electronic fitting

    XS4 One electronic fitting

  • XS4 Mini electronic fitting

    XS4 Mini electronic fitting

  • SALTO Neo digital cylinder

    SALTO Neo digital cylinder

  • XS wall reader

    XS wall reader

In use

  • Electronic fitting on an interior door

    Electronic fitting on an interior door

  • Opening with a card at the digital cylinder

    Opening with a card at the digital cylinder

  • Digital cylinder on a glass door

    Digital cylinder on a glass door

  • Electronic fitting in an office corridor

    Electronic fitting in an office corridor

Access down to the individual cabinet

We retrofit server cabinets with digital half cylinders. Each cabinet is given its own permissions, and every opening is logged. For areas with a high protection requirement, the BABYLON access control system from AUTEC is available, which according to the manufacturer is designed to meet the requirements of the BSI.

Swing handle with digital half cylinder for server cabinets
More about access control

Early fire detection with aspirating smoke detection for server cabinets

We install fire detection systems with aspirating smoke detection for server rooms and server cabinets and take over the support of existing systems.

Overview of an ESSER fire detection system: alarm devices, fire control functions, fire brigade peripherals, special detectors and networking

Support and takeover of existing systems

  • Quarterly inspection and annual maintenance to DIN VDE 0833-1 and DIN 14675
  • Emergency service line around the clock for faults
  • Monitoring of the fire alarm panel network, including connection to an app
  • Organisation of the recurring inspection by accredited inspection experts
  • Replacement or migration of legacy systems
  • Replacement or factory testing of automatic smoke detectors to DIN 14675-1: after 5 years without contamination compensation, after 8 years with contamination compensation

Installation of new systems

  • Construction and commissioning of fire detection systems
  • Coordination with the local fire brigade
  • Complete project management and cost control
  • Integration and monitoring of third-party systems

We are a regional support centre for the fire detection manufacturers Honeywell Esser, Detectomat, Telenot, Hekatron and Notifier.

More about fire detection

Digital video recording systems for data centres

Digital video recording systems complement zone monitoring and provide the images for checking alarms and for later evaluation. Before installation we prepare a camera plan with a field-of-view simulation. It defines which camera covers which area and avoids blind spots as well as over-equipment.

The GDPR does not set a fixed retention period. The data protection supervisory authorities generally consider up to 72 hours appropriate, and longer retention needs a justification. We set up the retention period, user permissions and privacy masking to your specifications. If your certification framework or your customer requires longer retention, document the justification in your data protection concept.

Workstation with video management and an access event

Examples of use

  • Video management at the desk

    Video management at the desk

  • Control desk with site plan and live images

    Control desk with site plan and live images

  • Camera on the façade

    Camera on the façade

  • Camera in the stairwell

    Camera in the stairwell

  • Dome camera at the entrance

    Dome camera at the entrance

  • Compact camera on the building shell

    Compact camera on the building shell

  • Camera above the cable trays

    Camera above the cable trays

  • Camera in the aisle between the server cabinets

    Camera in the aisle between the server cabinets

More about video surveillance

Building shell and security zone monitoring to VdS

We are a specialist installer of intruder alarm systems recognised by VdS. We design and install the systems to VdS guidelines and agree the security concept with your insurer. Alarms are transmitted in encrypted form to an alarm receiving centre. Arming is done at contactless readers.

System overview of the TELENOT hiplex 8400H intruder alarm control panel

Planning and installation to VdS guidelines

  • Maintenance and inspection of the intruder alarm system
  • Emergency service line around the clock for faults
  • Monitoring of the intruder alarm network, including connection to an app
  • Contactless readers for arming
  • VdS installation attestation (VdS-Attest) for your insurer
  • Transmission of alarms to the alarm receiving centre

Use of intelligent detectors

  • 360-degree and volumetric motion detectors
  • Magnetic and bolt contacts
  • Active and passive glass break detectors
  • Seismic and vibration detectors

Alarm signalling

  • Visual alarm device on the façade

    Visual alarm device on the façade

More about intruder detection

Security zones from the site to the server cabinet

The physical security of a data centre follows the onion principle. Perimeter and vehicle entrance, building envelope, data centre floor, room and the individual cabinet form successive zones.

Each zone has its own access check up to multi-factor authentication, its own video surveillance and its own logging. An attacker would have to overcome each layer individually, and each layer raises its own alarm.

Operators and their customers usually base this on EN 50600, BSI IT-Grundschutz, criteria catalogues such as TSI or ISO 27001. We align the security concept with the framework you specify. Certification itself is carried out by the relevant certification body.

Early fire detection with aspirating smoke detection

An aspirating smoke detection system continuously draws air samples from the room or cabinet and detects a smouldering fire considerably earlier than a point detector, before open flames develop. This gives time to shut down affected components selectively.

We design and install new fire alarm systems as a specialist company certified to DIN 14675. We handle construction and commissioning, coordination with the local fire brigade, project management with cost control and the connection to the fire brigade or an alarm receiving centre.

We take over the care of existing systems, including those installed by another company. We are a regional support centre (Regiostützpunkt) for the manufacturers Honeywell Esser, Detectomat, Telenot, Hekatron and Notifier.

  • Quarterly inspection and annual maintenance to DIN VDE 0833-1 and DIN 14675
  • Emergency service line around the clock for faults
  • Monitoring of the fire alarm panel network, including connection to an app
  • Organisation of the recurring inspection by accredited inspection experts
  • Replacement or migration of legacy systems
  • Replacement or factory testing of automatic smoke detectors to DIN 14675-1: after 5 years without contamination compensation, after 8 years with contamination compensation
  • Integration and monitoring of third-party systems

Standards and certifications

  • VdS
  • DIN 14675

Manufacturers and systems

  • SALTO Systems
  • AUTEC
  • Honeywell Esser
  • Detectomat
  • Telenot
  • Hekatron
  • Notifier

Frequently asked questions

How early does an aspirating smoke detection system detect a fire in the server cabinet?

Considerably earlier than a point detector. The system continuously draws air samples directly from the cabinet and detects even small quantities of smoke particles before open flames develop.

Which standards apply to the physical security of data centres?

The main frameworks are EN 50600, BSI IT-Grundschutz and, depending on the certification target, criteria catalogues such as TSI. VdS guidelines also apply to the building envelope and security areas. These are requirements that you or your customers define. We design the security technology to match the certification level you are aiming for.

How does a security zone concept from the site to the rack work?

According to the onion principle: perimeter and vehicle entrance, building envelope, data centre floor, room and cabinet form successive zones. Each has its own access check, video surveillance and logging, and each raises its own alarm.

How do we prove physical security to customers and auditors?

Through consistent logging. Access events, alarms and maintenance are documented traceably and can be compiled as a report for ISO 27001 audits, customer audits or insurers. Video recordings are available within the defined retention period.