Data centres
Multi-level access and seamless monitoring.

In a data centre, what matters is who was at which cabinet and when, and how early a smouldering fire is detected. We install access control down to the individual server cabinet, early fire detection with aspirating smoke detection, video recording and monitoring of the building envelope and security zones to VdS.
- Access down to the rackDigital half cylinders allow individual permissions for each server cabinet.
- Early fire detection in the cabinetAspirating smoke detection systems continuously draw air samples from the server cabinet and detect a smouldering fire at an early stage.
- Intruder detection to VdSWe design and install the monitoring of the building envelope and security zones to VdS guidelines.
- Evidence for auditsAccess events and maintenance are logged and can be compiled as a report.
Protection in four shells
A security concept works from the outside in. Each shell detects earlier and buys time to respond.
1. PerimeterFence, gates, entrances
2. Open groundsVideo, radar, lighting
3. Building shellIntrusion alarm, access
4. Interior zonesAccess zones, fire, asset protection
Security zones from the site to the server cabinet
The physical security of a data centre follows the onion principle. Perimeter and vehicle entrance, building envelope, data centre floor, room and the individual cabinet form successive zones.
Each zone has its own access check up to multi-factor authentication, its own video surveillance and its own logging. An attacker would have to overcome each layer individually, and each layer raises its own alarm.
Operators and their customers usually base this on EN 50600, BSI IT-Grundschutz, criteria catalogues such as TSI or ISO 27001. We align the security concept with the framework you specify. Certification itself is carried out by the relevant certification body.
Electronic access control and locking systems
With the SALTO Space system platform, doors, gates, lifts, vehicle entrances and furniture can be integrated into one uniform, wireless access control system. Mechanical keys are no longer needed. Permissions are granted and withdrawn centrally in web-based software, including for several sites. We are a certified OEM partner of SALTO.
We retrofit server cabinets with digital half cylinders. Each cabinet is given its own permissions, and every opening is logged. For areas with a high protection requirement, the BABYLON access control system from AUTEC is available, which according to the manufacturer is designed to meet the requirements of the BSI.
- Retrofitting with digital cylinders or digital fittings
- Multi-tenant web software
- Opening by RFID chip or smartphone
- Installation without cabling the doors
- Individual permissions for each server cabinet
Early fire detection with aspirating smoke detection
An aspirating smoke detection system continuously draws air samples from the room or cabinet and detects a smouldering fire considerably earlier than a point detector, before open flames develop. This gives time to shut down affected components selectively.
We design and install new fire alarm systems as a specialist company certified to DIN 14675. We handle construction and commissioning, coordination with the local fire brigade, project management with cost control and the connection to the fire brigade or an alarm receiving centre.
We take over the care of existing systems, including those installed by another company. We are a regional support centre (Regiostützpunkt) for the manufacturers Honeywell Esser, Detectomat, Telenot, Hekatron and Notifier.
- Quarterly inspection and annual maintenance to DIN VDE 0833-1 and DIN 14675
- Emergency service line around the clock for faults
- Monitoring of the fire alarm panel network, including connection to an app
- Organisation of the recurring inspection by accredited inspection experts
- Replacement or migration of legacy systems
- Replacement or factory testing of automatic smoke detectors to DIN 14675-1: after 5 years without contamination compensation, after 8 years with contamination compensation
- Integration and monitoring of third-party systems
Building envelope, security zones and video recording
We are a specialist installer of intruder alarm systems recognised by VdS. We design and install the systems to VdS guidelines and agree the security concept with your insurer. Alarms are transmitted in encrypted form to an alarm receiving centre. Arming is done at contactless readers.
Digital video recording systems complement zone monitoring and provide the images for checking alarms and for later evaluation. Before installation we prepare a camera plan with a field-of-view simulation. It defines which camera covers which area and avoids blind spots as well as over-equipment.
The GDPR does not set a fixed retention period. The data protection supervisory authorities generally consider up to 72 hours appropriate, and longer retention needs a justification. We set up the retention period, user permissions and privacy masking to your specifications. If your certification framework or your customer requires longer retention, document the justification in your data protection concept.
- Maintenance and inspection of the intruder alarm system
- Emergency service line around the clock for faults
- Monitoring of the intruder alarm network, including connection to an app
- VdS installation attestation (VdS-Attest) for your insurer
- 360-degree and volumetric motion detectors
- Magnetic and bolt contacts
- Active and passive glass break detectors
- Seismic and vibration detectors
Standards and certifications
- VdS
- DIN 14675
Manufacturers and systems
- SALTO Systems
- AUTEC
- Honeywell Esser
- Detectomat
- Telenot
- Hekatron
- Notifier
Frequently asked questions
How early does an aspirating smoke detection system detect a fire in the server cabinet?
Considerably earlier than a point detector. The system continuously draws air samples directly from the cabinet and detects even small quantities of smoke particles before open flames develop.
Which standards apply to the physical security of data centres?
The main frameworks are EN 50600, BSI IT-Grundschutz and, depending on the certification target, criteria catalogues such as TSI. VdS guidelines also apply to the building envelope and security areas. These are requirements that you or your customers define. We design the security technology to match the certification level you are aiming for.
How does a security zone concept from the site to the rack work?
According to the onion principle: perimeter and vehicle entrance, building envelope, data centre floor, room and cabinet form successive zones. Each has its own access check, video surveillance and logging, and each raises its own alarm.
How do we prove physical security to customers and auditors?
Through consistent logging. Access events, alarms and maintenance are documented traceably and can be compiled as a report for ISO 27001 audits, customer audits or insurers. Video recordings are available within the defined retention period.