Sectors
Prisons & forensic clinics
Cell security and personal protection.

For prisons and forensic clinics we bring fire alarm, intruder alarm, access and video technology together in the WinGuard hazard management system. We secure fences, walls and the approach area and design the technology for cells, wards and airlocks.
- WinGuard partner for central GermanyWe handle commissioning, training and support for the WinGuard hazard management system.
- Existing systems remain usableExisting technology stays in operation and is operated from one shared interface.
- Guided operationProcedural instructions lead staff through the actions step by step when an event occurs.
- Perimeter protection with zone locationFence sensors report the zone of the fence or wall top in which an alarm was triggered.
Protection in four shells
A security concept works from the outside in. Each shell detects earlier and buys time to respond.
1. PerimeterFence, gates, entrances
2. Open groundsVideo, radar, lighting
3. Building shellIntrusion alarm, access
4. Interior zonesAccess zones, fire, asset protection
Requirements in prisons and forensic clinics
In prisons and forensic clinics, many security systems work side by side: fire alarm systems, access control, intruder alarm systems, video and perimeter protection. They often come from different manufacturers and different years.
Staff in the control room must be able to assign events quickly, see the matching video image and initiate defined actions. Fences and walls must be monitored without gaps.
The technology runs around the clock and is subject to heavy use. Conversions have to be possible during operation and section by section.
Securing cells, wards and airlocks
In accommodation and ward areas, three things matter. Doors and passages must be controlled, a fire must be detected early and staff must be able to call for help at any time.
The technology for this comes from our disciplines. Access control and door monitoring regulate and log who opens which door and which airlock. Fire alarm systems to DIN 14675 monitor cells, corridors and functional rooms. Emergency and hold-up alarm devices with fixed buttons or mobile hand-held transmitters alert the control room.
The structural and organisational requirements for custody are set by the responsible justice administration. We design the technology to these requirements. We integrate existing systems from other manufacturers, such as communication or call systems, into hazard management where interfaces are available.
- Access control and status monitoring for doors and airlocks
- Early fire detection in cells, corridors and plant rooms
- Emergency and hold-up alarm devices for staff
- Electronic locking systems, also alongside existing mechanical locks
- Display of all messages on the control room's site plan
Higher-level hazard management with WinGuard
The WinGuard hazard management system from Advancis brings existing and new systems together on one interface. The platform is vendor-neutral and offers interfaces to a wide range of system types in fire detection, intruder detection, perimeter protection, video and access control. We clarify in an initial survey which of your systems can be connected.
We are the WinGuard partner for central Germany. During installation we integrate the existing technology, display the systems on floor plans, set up alarm and event messages and define forwarding rules and actions. Commissioning and training for your staff are included.
The system runs on workstations with several monitors, can be connected to video walls and can be used on a tablet or smartphone. All messages and entries are logged.
- Integration of existing fire alarm systems
- Visualisation and control of access control points
- Connection of intruder alarm systems
- Linking of live video images to events
- Logging and a ticket system for actions
Video surveillance and video management
We install digital video surveillance with a video management platform. For areas subject to heavy use such as corridors, yards and communal rooms we use vandal-resistant cameras. Before installation we prepare a camera plan with a field-of-view simulation. It defines which camera covers which area and avoids blind spots as well as over-equipment.
When a message arrives from access control, fire detection or the perimeter, hazard management brings up the matching live image. The control room can check an event before sending staff.
Where cameras may be used and how long images are stored is governed by the prison and data protection laws of the federal states. We set up user permissions, privacy masking, the four-eyes principle and deletion periods to your specifications.
Perimeter, fence and wall protection
We design, engineer, install and commission fence protection systems, including retrofits on existing fences and the monitoring of wall tops. The sensors report the zone of the fence in which an alarm was triggered. Depending on the model, one processing unit monitors fence lengths from several hundred metres to many kilometres.
Underground detection in the approach area works covertly. It reports digging, heavy vehicles nearby and people walking in the protected area. The triggered zone is displayed in hazard management.
No outdoor detection works entirely without false alarms. We therefore link the sensors to the video system so that every alarm can be checked on the live image before anyone is sent out.
- Site walk and agreement of the protection objective
- Design and engineering of the components
- Installation and commissioning
- Linking to the video system
- Retrofitting on existing fences
- Monitoring of wall tops
Standards and certifications
- DIN 14675
- VdS
Manufacturers and systems
- Advancis